Merge pull request #1311 from dagwieers/hpilo_facts-cleanup
hpilo_facts: Various clean ups in documentation and code
This commit is contained in:
commit
b1ccda00f8
1 changed files with 33 additions and 51 deletions
|
@ -37,51 +37,45 @@ options:
|
|||
login:
|
||||
description:
|
||||
- The login name to authenticate to the HP iLO interface.
|
||||
required: false
|
||||
default: Administrator
|
||||
password:
|
||||
description:
|
||||
- The password to authenticate to the HP iLO interface.
|
||||
required: false
|
||||
default: admin
|
||||
match:
|
||||
description:
|
||||
- An optional string to match against the iLO server name.
|
||||
- This is a safety measure to prevent accidentally using the wrong
|
||||
HP iLO interface with dire consequences.
|
||||
required: false
|
||||
examples:
|
||||
- code: |
|
||||
local_action: hpilo_facts host=$ilo_address login=$ilo_login password=$ilo_password match=$inventory_hostname_short
|
||||
only_if: "'$cmdb_hwmodel'.startswith('HP ')
|
||||
description: Task to gather facts from a HP iLO interface only if the system is an HP server
|
||||
- description: Typical output of HP iLO_facts for a physical system
|
||||
code: |
|
||||
- hw_bios_date: "05/05/2011"
|
||||
hw_bios_version: "P68"
|
||||
hw_eth0:
|
||||
- macaddress: "00:11:22:33:44:55"
|
||||
macaddress_dash: "00-11-22-33-44-55"
|
||||
hw_eth1:
|
||||
- macaddress: "00:11:22:33:44:57"
|
||||
macaddress_dash: "00-11-22-33-44-57"
|
||||
hw_eth2:
|
||||
- macaddress: "00:11:22:33:44:5A"
|
||||
macaddress_dash: "00-11-22-33-44-5A"
|
||||
hw_eth3:
|
||||
- macaddress: "00:11:22:33:44:5C"
|
||||
macaddress_dash: "00-11-22-33-44-5C"
|
||||
hw_eth_ilo:
|
||||
- macaddress: "00:11:22:33:44:BA"
|
||||
macaddress_dash: "00-11-22-33-44-BA"
|
||||
hw_product_name: "ProLiant DL360 G7"
|
||||
hw_product_uuid: "ef50bac8-2845-40ff-81d9-675315501dac"
|
||||
hw_system_serial: "ABC12345D6"
|
||||
hw_uuid: "123456ABC78901D2"
|
||||
- description: Task to gather facts from a HP iLO interface only if the system is an HP server
|
||||
code: |
|
||||
- local_action: hpilo_facts host=$ilo_address login=$ilo_login password=$ilo_password
|
||||
only_if: "'$cmdb_hwmodel'.startswith('HP ')
|
||||
- local_action: fail msg="CMDB serial ($cmdb_serialno) does not match hardware serial ($hw_system_serial) !"
|
||||
only_if: "'$cmdb_serialno' != '$hw_system_serial'"
|
||||
- description: Typical output of HP iLO_facts for a physical system
|
||||
code: |
|
||||
- hw_bios_date: "05/05/2011"
|
||||
hw_bios_version: "P68"
|
||||
hw_eth0:
|
||||
- macaddress: "00:11:22:33:44:55"
|
||||
macaddress_dash: "00-11-22-33-44-55"
|
||||
hw_eth1:
|
||||
- macaddress: "00:11:22:33:44:57"
|
||||
macaddress_dash: "00-11-22-33-44-57"
|
||||
hw_eth2:
|
||||
- macaddress: "00:11:22:33:44:5A"
|
||||
macaddress_dash: "00-11-22-33-44-5A"
|
||||
hw_eth3:
|
||||
- macaddress: "00:11:22:33:44:5C"
|
||||
macaddress_dash: "00-11-22-33-44-5C"
|
||||
hw_eth_ilo:
|
||||
- macaddress: "00:11:22:33:44:BA"
|
||||
macaddress_dash: "00-11-22-33-44-BA"
|
||||
hw_product_name: "ProLiant DL360 G7"
|
||||
hw_product_uuid: "ef50bac8-2845-40ff-81d9-675315501dac"
|
||||
hw_system_serial: "ABC12345D6"
|
||||
hw_uuid: "123456ABC78901D2"
|
||||
notes:
|
||||
- This module ought to be run from a system that can access the HP iLO
|
||||
interface directly, either by using C(local_action) or
|
||||
C(using delegate)_to.
|
||||
interface directly, either by using local_action or
|
||||
using delegate_to.
|
||||
'''
|
||||
|
||||
import sys
|
||||
|
@ -92,7 +86,7 @@ except ImportError:
|
|||
print "failed=True msg='hpilo python module unavailable'"
|
||||
sys.exit(1)
|
||||
|
||||
### Surpress warnings from hpilo
|
||||
# Surpress warnings from hpilo
|
||||
warnings.simplefilter('ignore')
|
||||
|
||||
def main():
|
||||
|
@ -102,27 +96,15 @@ def main():
|
|||
host = dict(required=True),
|
||||
login = dict(default='Administrator'),
|
||||
password = dict(default='admin'),
|
||||
match = dict(default=None),
|
||||
)
|
||||
)
|
||||
|
||||
host = module.params.get('host')
|
||||
login = module.params.get('login')
|
||||
password = module.params.get('password')
|
||||
match = module.params.get('match')
|
||||
|
||||
ilo = hpilo.Ilo(host, login=login, password=password)
|
||||
|
||||
# If match=string is provided, only reboot server if iLO name matches 'string'
|
||||
if match != None:
|
||||
try:
|
||||
server_name = ilo.get_server_name()
|
||||
except Exception, e:
|
||||
module.fail_json(rc=1, msg='Failed to connect to %s: %s' % (host, e.message))
|
||||
|
||||
if not server_name.lower().startswith(match.lower()):
|
||||
module.fail_json(rc=1, msg='The iLO server name \'%s\' does not match \'%s\'' % (server_name, match))
|
||||
|
||||
# TODO: Count number of CPUs, DIMMs and total memory
|
||||
data = ilo.get_host_data()
|
||||
facts = {
|
||||
|
@ -135,7 +117,7 @@ def main():
|
|||
facts['hw_bios_date'] = entry['Date']
|
||||
elif entry['type'] == 1: # System Information
|
||||
facts['hw_uuid'] = entry['UUID']
|
||||
facts['hw_system_serial'] = entry['Serial Number']
|
||||
facts['hw_system_serial'] = entry['Serial Number'].rstrip()
|
||||
facts['hw_product_name'] = entry['Product Name']
|
||||
facts['hw_product_uuid'] = entry['cUUID']
|
||||
elif entry['type'] == 209: # Embedded NIC MAC Assignment
|
||||
|
|
Loading…
Reference in a new issue