* openshift inventory: fix exception when auth fails
Fix 'ForbiddenError' object has no attribute 'message':
[WARNING]: * Failed to parse test.yml with openshift plugin: 'ForbiddenError' object has no attribute 'message'
File "ansible/lib/ansible/inventory/manager.py", line 270, in parse_source
plugin.parse(self._inventory, self._loader, source, cache=cache)
File "ansible/lib/ansible/plugins/inventory/openshift.py", line 122, in parse
self.setup(config_data, cache, cache_key)
File "ansible/lib/ansible/module_utils/k8s/inventory.py", line 58, in setup
self.fetch_objects(connections)
File "ansible/lib/ansible/module_utils/k8s/inventory.py", line 250, in fetch_objects
super(OpenShiftInventoryHelper, self).fetch_objects(connections)
File "ansible/lib/ansible/module_utils/k8s/inventory.py", line 81, in fetch_objects
namespaces = self.get_available_namespaces(client)
File "ansible/lib/ansible/module_utils/k8s/inventory.py", line 95, in get_available_namespaces
raise K8sInventoryException('Error fetching Namespace list: {0}'.format(exc.message))
Don't try to get 'message' attribute from:
- K8sInventoryException instances
- Exception instances
- KubernetesException instances (because KubernetesException can be
Exception)
* move k8s/OpenShift inventory plugin dedicated code
inventory plugin specific code should not be located in
lib/ansible/module_utils directory. Then ansible.utils methods can be
reused (for example Display).
* Remove unused class variables 'helper'
unused since 4d77878654.
* Update win_robocopy.py
<!--- Show example of UNC path copy of a single file, noting trailing backslash required -->
+label: docsite_pr
* addresses jborean comment, removes double quotes
* Remove trailing slash part
* Added feature facts to nxos_facts
* Fixed ansibot indentation
* Resolved ansibot whitespace missing after ','
* Per PR suggestion, created method in base class to gather switch config
and store in global variable to prevent multiple calls to switch.
* Addressed ansibot blank line & whitespace after ,
* Enable support for launch_templates in ec2_asg
* Fix asg create with LT and no version number
* Update mutually exclusive list
* Better function names
Maintain one Templar for the lifetime of VariableManager, calling
set_available_variables() prior to each use, enabling _get_filter()'s
cache to function correctly.
It does not seem possible for concurrent calls into one (non-copied)
VariableManager instance, and so it need not be reentrant. If that
became a requirement, serializing its or Templar's entry points would be
fine, as it's so CPU-heavy other threads will only fight with it for the
GIL anyway.
Reduces _get_filters() runtime 91%, get_vars() runtime 19%, function
call count 16%, overall runtime 10%.
Tested aginst dummy load comprised of the 12 disabled steps of
debops.auth with an inventory of 80 hosts, which stresses variable
processing and task setup. Before:
7447296 function calls (7253994 primitive calls) in 32.611 seconds
Ordered by: cumulative time
ncalls tottime percall cumtime percall filename:lineno(function)
1 0.000 0.000 32.762 32.762 ansible-playbook:3(<module>)
1 0.007 0.007 31.733 31.733 ansible-playbook:21(<module>)
...
1371/971 0.671 0.000 21.332 0.022 manager.py:154(get_vars)
...
3044 0.315 0.000 5.166 0.002 __init__.py:295(_get_filters)
After:
6252978 function calls (6059638 primitive calls) in 29.055 seconds
Ordered by: cumulative time
ncalls tottime percall cumtime percall filename:lineno(function)
1 0.000 0.000 29.218 29.218 ansible-playbook:3(<module>)
1 0.007 0.007 28.159 28.159 ansible-playbook:21(<module>)
...
1371/971 0.675 0.000 17.211 0.018 manager.py:154(get_vars)
...
3044 0.028 0.000 0.441 0.000 __init__.py:295(_get_filters)
* allow jinja2 unique filter compat
* detect if unique is provided, fallback with warning
* handle j2 specific params
* now all filters using unique must pass environment
* added env to tests
also normalized on how we normally import and use exceptoins
* Start of work on pylint plugin to catch due/past-due deprecated calls
* Improve deprecated pylint plugin
* Catch call to AnsibleModule.deprecate also
* Skip splatted kwargs, we can't infer that info
* Add error for invalid version in deprecation
* Skip version if it's a reference to a var
* Disable ansible-deprecated-no-version for displaying deprecated module info
* fix comments
* is None
* Force specifying a version, this can be disabled on a per case basis
* Disable ansible-deprecated-version by default
* Remove to look for 2.8 deprecated
* Revert "Remove to look for 2.8 deprecated"
This reverts commit 4e84034fd1.
* Add script and template used for creating issues for deprecated issues
* Fix underscore var
* Update synchronize.py
If you want a different rsync binary on the local side, you need to set task variable ansible_rsync_path.
See examples.
Variable ansible_rsync_path looks to not be documented anywhere. If documented, needs to be said that is does not belong to synchronise options, instead belongs to tasks. (Sorry, I have no better wording)
* [rabbitmq_binding] Fix the quoting of vhost and other names, which was broken in PR #35651
* Merge missing urllib_parse.quote from PR #42422
* Missed one line, where also needs to be escaped, i.e., the destination
* Various changes to nxos_logging. Plus added purge capibility.
* Made a few new nxapi_logging test cases conditional based on version
and/or platform.
* Addressed PR comments and ansibot shippable. Fixed up nxos_logging documentation format.
* Addressed ansibot shippable issues with whitespaces and documentation.
* Resolved ansibot codestyle trailing whitespace
* adds support for null values to the ternary filter
This change adds a third optional argument to the ternary filter to
handle a null value. If the third option is specified null and false
are treated differently.
For instance, take the following example:
{{ enabled | ternary('no shutdown', 'shutdown') }}
If enabled == True, then 'no shutdown' is used.
If enabled in (False, None), then 'shutdown' is used.
With this change the following is possible:
{{ enabled | ternary('no shutdown', 'shutdown', omit) }}
If enabled == True, then 'no shutdown'
If enabled == False, then 'shutdown'
If enabled == None, then omit
* update documentation with example of filter
* update filter documentation example per comments
* fix logic error in user_guide example
* Ensure that the value of PLUGIN_FILTERS_CFG is treated as type=path, and that we use the standard section of 'defaults' instead of 'default'
* deprecate the default section
* Don't add version_added for the corrected section