ansible/test/integration/targets/vmware_vswitch/tasks/main.yml
Gonéri Le Bouder 6bb21c3db0 vmware: test-refactoring
- In order to keep the integration with `ansible-test`, we prefer to avoid any
  interaction with the Ansible inventory file.
- split up the prepare_vmware_tests/defaults/main.yml in two
  configuration files: one for vcsim and one for a real environment
- remove all the access to hostvars
- directly interact with the ESXi to mount/umount the datastore
  https://github.com/ansible/ansible/pull/56516
- record the virtual machine folder in the environment configuration
- vmware_guest_move: Use https://github.com/ansible/ansible/pull/55237
2019-05-23 17:40:19 -04:00

114 lines
3 KiB
YAML

# Test code for the vmware_vswitch module.
# Copyright: (c) 2017, Abhijeet Kasurde <akasurde@redhat.com>
# GNU General Public License v3.0+ (see COPYING or https://www.gnu.org/licenses/gpl-3.0.txt)
- when: vcsim is not defined
block:
- import_role:
name: prepare_vmware_tests
vars:
setup_attach_host: true
# TODO: akasurde: VCSIM does not suport network manager system
# FIXME: Implement check-mode support
- name: Add a nic to a switch
vmware_vswitch:
hostname: '{{ esxi1 }}'
username: '{{ esxi_user }}'
password: '{{ esxi_password }}'
validate_certs: no
switch: vmswitch_0001
nics: vnic_1
state: present
register: add_nic_run
- assert:
that:
- add_nic_run.changed == true
- name: Add a nic to a switch again
vmware_vswitch:
hostname: '{{ esxi1 }}'
username: '{{ esxi_user }}'
password: '{{ esxi_password }}'
validate_certs: no
switch: vmswitch_0001
nics: vnic_1
state: present
register: add_nic_again_run
- assert:
that:
- add_nic_again_run.changed == false
- name: Remove a switch (check-mode)
vmware_vswitch:
hostname: '{{ esxi1 }}'
username: '{{ esxi_user }}'
password: '{{ esxi_password }}'
validate_certs: no
switch: vmswitch_0001
state: absent
check_mode: yes
register: remove_nic_check
# FIXME: Implement check-mode support
- assert:
that:
- remove_nic_check.changed == true
# FIXME: Removing a switch fails
- name: Remove a switch
vmware_vswitch:
hostname: '{{ esxi1 }}'
username: '{{ esxi_user }}'
password: '{{ esxi_password }}'
validate_certs: no
switch: vmswitch_0001
state: absent
register: remove_nic_run
- assert:
that:
- remove_nic_run.changed == true
- name: Remove a switch again (check-mode)
vmware_vswitch:
hostname: '{{ esxi1 }}'
username: '{{ esxi_user }}'
password: '{{ esxi_password }}'
validate_certs: no
switch: vmswitch_0001
state: absent
check_mode: yes
register: remove_nic_again_check
# FIXME: Implement check-mode support
- assert:
that:
- remove_nic_again_check_mode.changed == false
# FIXME: Removing a switch fails
- name: Remove a switch again
vmware_vswitch:
hostname: '{{ esxi1 }}'
username: '{{ esxi_user }}'
password: '{{ esxi_password }}'
validate_certs: no
switch: vmswitch_0001
state: absent
register: remove_nic_again_run
- assert:
that:
- remove_nic_again_run.changed == false
- name: Add vswitch to a specific host system
vmware_vswitch:
validate_certs: False
hostname: '{{ esxi1 }}'
username: '{{ esxi_user }}'
password: '{{ esxi_password }}'
switch: vmswitch_0002
nics: vnic_1
esxi_hostname: guest1
register: add_vswitch_with_host_system
- debug: var=add_vswitch_with_host_system
- assert:
that:
- add_vswitch_with_host_system.changed == true