From b2be7ffe423a070a9d6ebbd4f5759df001369b12 Mon Sep 17 00:00:00 2001 From: aidancbrady Date: Sat, 13 Jun 2015 12:39:23 -0400 Subject: [PATCH] Fixed Universal Cable IC2 interaction, Solar Evaporation Plants now cool down half as fast as they did previously, also continue to operate with internal heat at night --- src/main/java/mekanism/common/EnergyNetwork.java | 2 ++ .../java/mekanism/common/base/EnergyAcceptorWrapper.java | 7 ++++++- .../common/tile/TileEntitySolarEvaporationController.java | 4 ++-- 3 files changed, 10 insertions(+), 3 deletions(-) diff --git a/src/main/java/mekanism/common/EnergyNetwork.java b/src/main/java/mekanism/common/EnergyNetwork.java index e7e239f96..9eeb2ff22 100644 --- a/src/main/java/mekanism/common/EnergyNetwork.java +++ b/src/main/java/mekanism/common/EnergyNetwork.java @@ -133,10 +133,12 @@ public class EnergyNetwork extends DynamicNetwork 18 || inputTank.getFluid() == null || getTempMultiplier() == 0) + if(!structured || height < 3 || height > 18 || inputTank.getFluid() == null) { return false; } @@ -314,7 +314,7 @@ public class TileEntitySolarEvaporationController extends TileEntitySolarEvapora if(getTempMultiplier() == 0) { - temperature = Math.max(0, getTemperature()-(max/WARMUP)); + temperature = Math.max(0, getTemperature()-(max/(WARMUP*2))); } else { temperature = Math.min(max, getTemperature()+incr);