add hu config
This commit is contained in:
parent
f4ee738f39
commit
f736f8ae2b
|
@ -35,6 +35,18 @@ public class SPConfig {
|
|||
public final ForgeConfigSpec.IntValue steelFlywheelSpeed;
|
||||
public final ForgeConfigSpec.IntValue steelFlywheelSteamConsumptionPerTick;
|
||||
public final ForgeConfigSpec.IntValue steelFlywheelSteamStorage;
|
||||
|
||||
public final ForgeConfigSpec.IntValue HUPerFuelTick;
|
||||
public final ForgeConfigSpec.DoubleValue steamPerWater;
|
||||
|
||||
public final ForgeConfigSpec.IntValue bronzeBoilerHU;
|
||||
public final ForgeConfigSpec.IntValue castIronBoilerHU;
|
||||
public final ForgeConfigSpec.IntValue steelBoilerHU;
|
||||
|
||||
public final ForgeConfigSpec.IntValue bronzeBurnerHU;
|
||||
public final ForgeConfigSpec.IntValue castIronBurnerHU;
|
||||
public final ForgeConfigSpec.IntValue steelBurnerHU;
|
||||
|
||||
|
||||
public final ForgeConfigSpec.IntValue dynamoFeMaxIn;
|
||||
public final ForgeConfigSpec.IntValue dynamoFeMaxOut;
|
||||
|
@ -47,6 +59,29 @@ public class SPConfig {
|
|||
public final ForgeConfigSpec.DoubleValue steelCogwheelImpact;
|
||||
|
||||
Common(ForgeConfigSpec.Builder builder) {
|
||||
builder.push("steam");
|
||||
{
|
||||
HUPerFuelTick=builder.comment("HU generation for each fuel burning tick. 10HU=1mb of steam. THIS AFFECT ALL BURNERS AND BOILERS!")
|
||||
.defineInRange("HuPerFuelTick",24,0,655360);
|
||||
steamPerWater=builder.comment("This defines how many mbs of steam does a mb of water can turn into.")
|
||||
.defineInRange("steamPerWater",12.0,0.0,100000.0);
|
||||
|
||||
}
|
||||
builder.pop();
|
||||
builder.push("boiler").comment("Maximum HU the boiler intakes. 10HU=1mb of steam. ");
|
||||
{
|
||||
bronzeBoilerHU=builder.defineInRange("bronzeBoilerHu",120,0,1000000);
|
||||
castIronBoilerHU=builder.defineInRange("castIronBoilerHu",240,0,1000000);;
|
||||
steelBoilerHU=builder.defineInRange("steelBoilerHu",480,0,1000000);;
|
||||
}
|
||||
builder.pop();
|
||||
builder.push("burner").comment("Maximum HU the boiler emits. Note that this does not affect steam per fuel tick. 10HU=1mb of steam. ");
|
||||
{
|
||||
bronzeBurnerHU=builder.defineInRange("bronzeBurnerHu",120,0,1000000);
|
||||
castIronBurnerHU=builder.defineInRange("castIronBurnerHu",240,0,1000000);;
|
||||
steelBurnerHU=builder.defineInRange("steelBurnerHu",480,0,1000000);;
|
||||
}
|
||||
builder.pop();
|
||||
builder.push("flywheel");
|
||||
{
|
||||
builder.push("bronze_flywheel");
|
||||
|
|
Loading…
Reference in a new issue