0
0
Fork 1
mirror of https://mau.dev/maunium/synapse.git synced 2024-11-09 19:44:32 +01:00
synapse/tests/replication/tcp/streams/test_typing.py
Jonathan de Jong 4b965c862d
Remove redundant "coding: utf-8" lines (#9786)
Part of #9744

Removes all redundant `# -*- coding: utf-8 -*-` lines from files, as python 3 automatically reads source code as utf-8 now.

`Signed-off-by: Jonathan de Jong <jonathan@automatia.nl>`
2021-04-14 15:34:27 +01:00

153 lines
5.5 KiB
Python

# Copyright 2020 The Matrix.org Foundation C.I.C.
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
from unittest.mock import Mock
from synapse.handlers.typing import RoomMember
from synapse.replication.tcp.streams import TypingStream
from synapse.util.caches.stream_change_cache import StreamChangeCache
from tests.replication._base import BaseStreamTestCase
USER_ID = "@feeling:blue"
USER_ID_2 = "@da-ba-dee:blue"
ROOM_ID = "!bar:blue"
ROOM_ID_2 = "!foo:blue"
class TypingStreamTestCase(BaseStreamTestCase):
def _build_replication_data_handler(self):
return Mock(wraps=super()._build_replication_data_handler())
def test_typing(self):
typing = self.hs.get_typing_handler()
self.reconnect()
typing._push_update(member=RoomMember(ROOM_ID, USER_ID), typing=True)
self.reactor.advance(0)
# We should now see an attempt to connect to the master
request = self.handle_http_replication_attempt()
self.assert_request_is_get_repl_stream_updates(request, "typing")
self.test_handler.on_rdata.assert_called_once()
stream_name, _, token, rdata_rows = self.test_handler.on_rdata.call_args[0]
self.assertEqual(stream_name, "typing")
self.assertEqual(1, len(rdata_rows))
row = rdata_rows[0] # type: TypingStream.TypingStreamRow
self.assertEqual(ROOM_ID, row.room_id)
self.assertEqual([USER_ID], row.user_ids)
# Now let's disconnect and insert some data.
self.disconnect()
self.test_handler.on_rdata.reset_mock()
typing._push_update(member=RoomMember(ROOM_ID, USER_ID), typing=False)
self.test_handler.on_rdata.assert_not_called()
self.reconnect()
self.pump(0.1)
# We should now see an attempt to connect to the master
request = self.handle_http_replication_attempt()
self.assert_request_is_get_repl_stream_updates(request, "typing")
# The from token should be the token from the last RDATA we got.
assert request.args is not None
self.assertEqual(int(request.args[b"from_token"][0]), token)
self.test_handler.on_rdata.assert_called_once()
stream_name, _, token, rdata_rows = self.test_handler.on_rdata.call_args[0]
self.assertEqual(stream_name, "typing")
self.assertEqual(1, len(rdata_rows))
row = rdata_rows[0]
self.assertEqual(ROOM_ID, row.room_id)
self.assertEqual([], row.user_ids)
def test_reset(self):
"""
Test what happens when a typing stream resets.
This is emulated by jumping the stream ahead, then reconnecting (which
sends the proper position and RDATA).
"""
typing = self.hs.get_typing_handler()
self.reconnect()
typing._push_update(member=RoomMember(ROOM_ID, USER_ID), typing=True)
self.reactor.advance(0)
# We should now see an attempt to connect to the master
request = self.handle_http_replication_attempt()
self.assert_request_is_get_repl_stream_updates(request, "typing")
self.test_handler.on_rdata.assert_called_once()
stream_name, _, token, rdata_rows = self.test_handler.on_rdata.call_args[0]
self.assertEqual(stream_name, "typing")
self.assertEqual(1, len(rdata_rows))
row = rdata_rows[0] # type: TypingStream.TypingStreamRow
self.assertEqual(ROOM_ID, row.room_id)
self.assertEqual([USER_ID], row.user_ids)
# Push the stream forward a bunch so it can be reset.
for i in range(100):
typing._push_update(
member=RoomMember(ROOM_ID, "@test%s:blue" % i), typing=True
)
self.reactor.advance(0)
# Disconnect.
self.disconnect()
# Reset the typing handler
self.hs.get_replication_streams()["typing"].last_token = 0
self.hs.get_tcp_replication()._streams["typing"].last_token = 0
typing._latest_room_serial = 0
typing._typing_stream_change_cache = StreamChangeCache(
"TypingStreamChangeCache", typing._latest_room_serial
)
typing._reset()
# Reconnect.
self.reconnect()
self.pump(0.1)
# We should now see an attempt to connect to the master
request = self.handle_http_replication_attempt()
self.assert_request_is_get_repl_stream_updates(request, "typing")
# Reset the test code.
self.test_handler.on_rdata.reset_mock()
self.test_handler.on_rdata.assert_not_called()
# Push additional data.
typing._push_update(member=RoomMember(ROOM_ID_2, USER_ID_2), typing=False)
self.reactor.advance(0)
self.test_handler.on_rdata.assert_called_once()
stream_name, _, token, rdata_rows = self.test_handler.on_rdata.call_args[0]
self.assertEqual(stream_name, "typing")
self.assertEqual(1, len(rdata_rows))
row = rdata_rows[0]
self.assertEqual(ROOM_ID_2, row.room_id)
self.assertEqual([], row.user_ids)
# The token should have been reset.
self.assertEqual(token, 1)